Product Advisory Notices and Obsolescence

Technology is always changing and as your premier automation distributor we want to try to keep you abreast of any product notifications and product obsolescence that may be occurring.

Of course, to have the most up to date information on your Rockwell Automation products, we suggest that you create a profile on Rockwell’s knowledgebase and request that all product notifications be sent directly to your email box.

MILWAUKEE® EXPANDS WARNINGS & INSTRUCTIONS FOR M18™ HIGH DEMAND™ 9.0 BATTERY PACK

In consultation with the U.S. Consumer Product Safety Commission (“CPSC”), Milwaukee Tool is voluntarily expanding the warnings and instructions for the MILWAUKEE M18 HIGH DEMAND 9.0 battery pack (model no. 48-11-1890).
If highly conductive or corrosive fluids get inside the M18 HIGH DEMAND 9.0 battery pack in sufficient quantities, they can cause the battery pack to fail. Failure can include short-circuit which, in the extreme situation, can result in smoking or fire, even when not in use. Examples of highly conductive or corrosive fluids include seawater, certain industrial chemicals and bleach or bleach-containing products.

This safety notice does not require users to return their M18 HIGH DEMAND 9.0 battery pack.

Milwaukee Tool is committed to your utmost safety while delivering the highest quality and most innovative products in the power tool industry.

For more information, go to www.milwaukeetool.com/safetynotices

Any customers who believe highly conductive or corrosive fluids have entered their M18 HIGH DEMAND 9.0 battery pack should immediately contact Milwaukee Tool at 1-844-577-5515 (7am to 10pm Eastern Time Sunday through Saturday).

OSHA Regulation On Respirable Crystalline Silica Dust

According to OSHA, over 2 million construction workers a year are exposed to crystalline silica dust. Found in materials like concrete, tile, rock, stone and brick, exposure to silica dust can be a major cause of a fatal cancer known as silicosis.

Starting September 23, 2017, the OSHA regulation on respirable crystalline silica dust (29 CFR 1926.1153) will be enforced for construction trades. This regulation reduces the Permissible Exposure LImit (PEL) to 50 pg/m3 over an 8-hour period and will affect jobsites nationwide.

Rockwell Automation - SequenceManager in Studio 5000 Logix Designer V28.00 Connection between Sequence and Phase Disconnects

This Product Notice informs you of an anomaly that exists with the SequenceManager in Studio 5000 Logix Designer V28.00.xx. When an ACD file containing sequence and phase programming is uploaded from a controller, the connection between the phase and the sequence disconnects. On subsequent downloads, this disconnection results in recipe changes from the sequence not being acted on by the phase in the controller.

Full correction of this anomaly requires upgrading your Studio 5000 Logix Designer to V28.01.00 or later. V28.01.00 is expected to be available for download from the Rockwell Automation Product Compatibility and Download Center (PCDC) on or before end of May 2016.

Osram Sylvania Recalls T8 LED Tubes Due to Fire Hazard

OSRAM SYLVANIA RECALLS T8 LED TUBES DUE TO FIRE HAZARD

WASHINGTON — The U.S. Consumer Product Safety Commission has recalled Osram Sylvania's T8 LED lamps due to overheating and melting. No injuries have been reported.

Recall Summary

Name of Product: T8 LED lamps

Hazard: Lamps can overheat and melt, posing a burn hazard.

Remedy: Replace

Consumers should immediately stop using the lamps, remove them from the fixture and immediately contact Osram Sylvania for a free replacement.

Consumer Contact: Osram Sylvania Inc. toll free at 877-423-3772 from 8 a.m. to 6 p.m. ET Monday through Friday or email ProductQuality@sylvania.com or www.sylvania.com and click on the Site Map in the bottom right-hand corner, then click on "Recall Safety Information" for more information.

Description: This recall involves SubstiTUBE IS T8 LED lamps. The recalled lamps are white, cylindrical in shape and measure 48 inches long and 1 inch in diameter. "OSRAM SubtiTUBE® IS LED T8" is printed on a silver label affixed to the end of lamps. The model number 73312-1 or 73315-1 also appears on the label beneath the statement "Compatible LED T8 for use with instant start T8 electronic ballasts."

Incidents/Injuries: Osram Sylvania Inc. received 34 reports of overheating and melting. No injuries have been reported.

Sold at: Osram Sylvania industrial/commercial distributors between December 2014 and May 2015.


Product Notice - PowerFlex 700H/S HiHP Intermittent False IOC Fault

This Product Notice informs you of a potential anomaly that exists with PowerFlex 700H and 700S HiHP (High Horsepower) Frames 10 14 AC Drives. In a small number of drives an intermittent false IOC instantaneous overcurrent fault may occur. When this occurs, the drive will initiate a safe shutdown. Drive operation may continue when the fault is cleared and the drive reset.

A potential anomaly exists with PowerFlex 700H and PowerFlex 700S HiHP AC Drives frame sizes 10-14. In a small number of drives an intermittent false instantaneous overcurrent (IOC) current fault may occur. When this occurs, the drive will initiate a safe shutdown and stop operating until the fault is cleared and the drive reset.

Customers who have verified they may have affected product as described in the steps listed in the Product Identification section of this document should contact the Rockwell Automation Technical Support Center at 262-512-8176 for further instructions.

PanelView Component Graphic Terminals Lifecycle Status Announcement

Rockwell Automation announces that as of 31-Jan-2016, the PanelView Component C1000 (10-inch) will be discontinued and no longer available for sale. And as of 30-Jun-2016, the PanelView Component C400 and C600 (4-inch and 6-inch), will be discontinued and no longer available for sale.

To support your transition, we recommend migrating to PanelView 800 graphic terminals. Similar to the PanelView Component, the PanelView 800 offers the same functionality and better performance of higher processor speed, higher memory and better display color and resolutions as listed in the table below.

Impacted products are as follows:

Catalog Number --- PanelView Component Description--- Discontinued Date--- Recommended Replacement --- PanelView 800 Description

2111C-T4T--- PanelView Component 4-Inch Terminal--- 30-June-2016---2711R-T4T--- PANELVIEW 800--- 4.3-INCH HMI TERMINAL

2711C-T6M--- PanelView Comp C600 Graphic Terminal--- 30-June-2016---2711R-T7---- PANELVIEW 80---- 7-INCH HMI TERMINAL

2711C-T6T--- PanelView Comp C600 Graphic Terminal--- 30-June-2016---2711R-T7T--- PANELVIEW 800--- 7-INCH HMI TERMINAL

2711C-T10C--- PanelView Comp C1000 Graphic Terminal--- 31-Jan-2016--- 2711R-T10T--- PANELVIEW 800--- 10.4-INCH HMI TERMINAL

You may want to plan for last-time buys as the discontinued date approaches.

Trusted T8160 TMR Interface Module May Not Start or May Stop during Operation

The affected products are: Trusted T8160 and T8160C TMR Interface Modules, also referred to as Regent Interface Modules (RIM), shipped between June 2006 and April 2015, hardware issue E or later.

The product catalog number, serial number, and hardware issue are located on the product nameplate, located on the side of the module. The product catalog number is located in the PROD No. field and will be one of T8160 or T8160C. The product serial number is located in the SERIAL No field. The product hardware issue level is in the H/W and will be E or later.

DESCRIPTION:
A potential anomaly exists with the Trusted T8160 and T8160C TMR Interface Module, also known as the Regent Interface Module (RIM), used to interface to Regent I/O subsystems. On some modules, internal component interconnections may loosen due to vibration or heat cycling during transit or operation. This may result in one or more of the three redundant systems in the module stopping during operation or not starting, as indicated by one or more of the "Healthy" LEDs on the front of the module flashing.

An affected module may intermittently start correctly but may subsequent stop operating during operation. Even though a module appears to be working correctly, modules identified by serial number as described in the Product Identification section of this document, must be returned for factory repair to correct the anomaly.

CORRECTION:
Customers should contact their Trusted system integrator and make arrangements to return product identified in the Product Identification section of this document for repair. Reference this Product Notice PN 2015-07-001 when requesting product repair services.

140-CMN Lifecycle Status Announcement

The Industrial Control Business is announcing the End of Life designation for the 140-CMN Motor Protection Circuit Breakers and related accessories effective 31 December 2015, with last-time-buy date 31 December 2015. Each of these 140-CMN Motor Protection Circuit Breakers is being placed into the End of Life status and has a recommended replacement of 140MG Motor Protection Circuit Breakers.

For more infomration on this product life cycle notice and the replacement products, please click here.

Discontinuation of Bulletin 1494V and 1494C 30A, 60A & 100A Visible Blade Disconnect Switches

In conjunction with the release of the new 1494U switch line, this provides official notification of the discontinuation plan of the 1494V Variable Depth and 1494C Cable Operated 30A, 60A and 100A Disconnect Switches.

30A, 60A and 100A Switch Components
• All 1494V and 1494C components will be available for order until February 29, 2016
• Examples: 1494V-DS30, 1494V-FS60, 1494C-CM11, etc…
• Effective March 1, 2016 all orders should be entered as the 1494U line
30A, 60A and 100A Switch Kits
• All 1494V and 1494C kits will be available for order until November 30, 2015
• Examples: 1494V-DR633-A-F, 1494C-DH611-B-D-E, etc…
• Effective December 1, 2015 all new kits should be configured and ordered as the 1494U line

For more information on this, please click here.

MicroLogix 1500 Controller Lifecycle Status Announcement

Rockwell Automation announces that as of 30 June 2017, the MicroLogix 1500 controller will be discontinued and no longer available for sale, with last-time-buy date of 30 June 2017.

To support your transition, we recommend migrating to MicroLogix 1400 or CompactLogix L1/L2 controller. Similar to the MicroLogix 1500, the MicroLogix 1400 or CompactLogix L1/L2 offers better functionality and more memory capacity.

Please contact your Revere Electric Product Specialist for assistance in the transition and migration.